Known Issues/P2402/Toyota

P2402 on Toyota

Evaporative Emission System Leak Detection Pump Control Circuit High

Minor2 Toyota models affected$150-$500 typical repairSystem: Emissions

P2402 on Toyota vehicles indicates evaporative emission system leak detection pump control circuit high. Au7o has documented this code across 2 Toyota models — most commonly on RAV4, Sienna. Generic code set when the PCM detects higher-than-expected voltage on the EVAP leak detection pump control circuit, usually from an open circuit or a short to a power source. The PCM cannot properly drive the pump to perform the EVAP leak test. Typical repair costs on Toyota range from $150 to $500, depending on the specific model and root cause.

Common Causes of P2402

  • •Open circuit or short to voltage in pump control wiring
  • •Failed EVAP leak detection pump
  • •Loose/corroded pump connector
  • •PCM driver fault

P2402 on Toyota by Model

Toyota RAV4(1 issue)

  • 2006-2010 RAV4 Liquid Fuel in EVAP System - T-SB-0046-102006-2010

    Toyota T-SB-0046-10 applies to specified 2006-2010 RAV4 production and addresses liquid fuel entering the EVAP system. The documented gates are an illuminated MIL with DTC P043E, P043F, P2401, P2402 and/or P2419, or an intermittent warm rough idle reproduced while commanding the purge VSV, followed by physical confirmation of fuel in the applicable EVAP vent hoses. It is not a general 2001-2012 charcoal-canister failure card and does not support the old P0440/P0441/P0442/P0446/P0455 mapping.

Toyota Sienna(1 issue)

  • EVAP System Leak-Detection / Vapor Canister Fault (Check Engine Light, Hard Refueling)2011-2020

    Third-generation Siennas commonly throw EVAP (evaporative emissions) faults as the system ages. Failure points include the canister vent solenoid/VSV sticking, the leak-detection pump and reference orifice, the purge valve, and a worn or loose gas cap. Beyond the check engine light and an emissions/smog failure, a stuck-closed vent can make the tank hard to refuel (pump clicks off repeatedly), while a stuck-open vent or cracked line can produce a fuel-vapor smell.

Looking for P2402 on a different make?

View P2402 across all makes →

Frequently Asked Questions

What does P2402 mean on Toyota?▼

P2402 stands for "Evaporative Emission System Leak Detection Pump Control Circuit High." Generic code set when the PCM detects higher-than-expected voltage on the EVAP leak detection pump control circuit, usually from an open circuit or a short to a power source. The PCM cannot properly drive the pump to perform the EVAP leak test. On Toyota specifically, this code is documented across 2 models.

What causes P2402 on Toyota vehicles?▼

Common causes on Toyota: Open circuit or short to voltage in pump control wiring, Failed EVAP leak detection pump, Loose/corroded pump connector, PCM driver fault. Specific causes vary by model and year — see the per-model sections below.

How much does it cost to fix P2402 on a Toyota?▼

Repair costs on Toyota range from $150 to $500, depending on the specific model and root cause.

Which Toyota models have P2402 documented?▼

Au7o has documented P2402 on 2 Toyota models: RAV4, Sienna.

Share:@au7o.io